2 Cubic Feet EO Gas Sterilizer

Description

In today’s healthcare environment, maintaining strict sterility standards for delicate instruments is non-negotiable. A 2 cubic feet EO gas sterilizer offers an efficient, compact solution specifically engineered for low-temperature sterilization of heat- and moisture-sensitive medical devices, supplies, and equipment. Ethylene oxide (EO) sterilization remains one of the most trusted methods for processing items that cannot withstand the high temperatures of steam autoclaves.

 

This compact ethylene oxide sterilizer uses a carefully controlled mixture of EO gas— a colorless, highly penetrating gas— combined with inert diluents such as carbon dioxide (CO₂) or nitrogen. The inert gas significantly reduces flammability risks while maintaining the sterilant’s effectiveness. EO works by alkylating the DNA and proteins of microorganisms, including bacteria, viruses, fungi, and spores, rendering them unable to reproduce or function. Its excellent penetration capability allows it to reach deep inside complex instruments, lumens, and sealed packaging materials.

 

With a chamber volume of approximately 2 cubic feet, this size EO gas sterilizer is perfectly suited for small to medium healthcare facilities. Clinics, dental offices, veterinary practices, research laboratories, and outpatient surgery centers benefit most from its space-saving design without sacrificing sterilization capacity.

Working Principle of 2 Cubic Feet EO Gas Sterilizer

Core Advantages Over Steam Sterilization

  • Low-Temperature & Moisture-Free Processing: Operating safely at a gentle 50 degrees Celsius without steam or high heat, this dry and cold cycle prevents thermal distortion or moisture damage.
  • Superior Material Penetration: ETO molecules possess exceptional diffusive properties, allowing deep penetration into complex lumens, multi-channel tubing, and tightly packaged medical apparatus.
  • Preservation of Delicate and High-Value Devices: Ideal for delicate instruments—such as cardiac catheters, vascular stents, intraocular lenses (IOLs), specialized diagnostic scopes, and precision microsurgical tools.
  • Extended Asset Lifespan: The non-corrosive chemical mechanism safeguards sensitive surgical accessories and single-use-capable disposables against heat fatigue, maximizing their safe reusable lifecycle.

 

Machine Configurations and Types

As a premier manufacturer based in India, our production line encompasses two distinct operational models tailored to varying facility requirements:

 

  • Semi-Automatic EtO Sterilizer: Engineered with intuitive analog push-buttons and manual control switches on the fascia panel, offering a straightforward, robust interface for operator-managed cycle execution.

 

  • Fully Automatic EtO Sterilizer: Powered by an advanced PLC and touch-screen HMI architecture, this variant delivers hands-free process automation, digital batch recipe tracking, and precise parameter oversight directly from the graphical interface.

Technical Specification of 2 Cubic Feet EO Gas Sterilizer

Model

AETOS – 2.6

AETOS – 4.5

AETOS – 8

Working Capacity in Cu. Ft.

2.6

4.5

8

Working Volume

70 Liters

125 Liters

200 Liters

Chamber Size

12” (W) x 12” (H) x 32”

 

12” (W) x 12” (H) x 54” (D) OR

15” (W) x 15” (H) x 36” (D)

20” (W) x 18” (H) x 38” (D) OR

16” (W) x 16” (H) x 54” (D)

Sterilant Gas

40 grams cartridge

100 grams cartridge

170 grams cartridge

Sterilization Cycle

Warm & Cold Cycles are possible.

Warm & Cold Cycles are possible.

Warm & Cold Cycles are possible.

Aeration

In-built aeration facility provided.

In-built aeration facility provided.

In-built aeration facility provided.

Utility

Compressed Air (100 psig)

Compressed Air (100 psig)

Compressed Air (100 psig)

Power Supply

1 K.W.

2 K.W.

2.5 K.W.

Power Voltage

220 volts, Single Phase, 50 Hertz

220 volts, Single Phase, 50 Hertz

220 volts, Single Phase, 50 Hertz

* Power voltage can be adjusted as per customer’s domestic power voltage requirements.
* Rights of technical improvements & modification reserved.
* Illustrations & dimensions are shown for information purpose only.

Types of Sterilization Equipment

Applications of Sterilization Equipment

Benefits of 2 Cubic Feet EO Gas Sterilizer

Safe for plastics, rubber, electronics, optics, and delicate catheters that would be damaged by steam or dry heat.

Items can be sterilized in their final packaging, maintaining sterility until point of use.

Effective against a broad spectrum of pathogens, including resistant spores.

The 2 cubic feet capacity fits easily into space-constrained facilities while handling daily sterilization needs for smaller practices.

Key Features of 2 Cubic Feet EO Gas Sterilizer

  • Chamber Construction: Usually double-walled stainless steel with insulation for safety and efficiency. Includes controls for vacuum evacuation, gas injection, aeration, and exhaust.

 

  • Typical Cycle Phases:
    • Air Removal: Vacuum pump eliminates air to prevent flammability.
    • Conditioning: Humidification and heating (around 30–60°C) to optimize EO penetration.
    • EO Exposure: Gas injection (e.g., 10–20% EO mixture) for 1–2 hours dwell.
    • Aeration/Purge: Fresh air flush to remove EO residues, often with active aeration for faster off-gassing.

 

  • Safety Features: Explosion-proof design, leak detectors, automatic shutoffs, and compliance with standards like ATEX and ISO 11135.

 

  • Load Capacity: Suitable for items like syringes, catheters, sutures, endoscopes, pacemakers, or small batches of plastics/bandages. Wrapped loads can have a shelf life of 3+ months.

FAQ for 2 Cubic Feet EO Gas Sterilizer

The sterilizer uses a controlled mixture of ethylene oxide gas with inert diluents such as carbon dioxide or nitrogen. EO alkylates the DNA and proteins of microorganisms (bacteria, viruses, fungi, and spores), preventing them from reproducing. The process includes vacuum air removal, conditioning (humidification and heating around 30–60°C), EO exposure, and aeration to remove residual gas.

EO sterilization operates at a gentle ~50°C without steam or high heat, preventing thermal distortion or moisture damage to delicate items. It offers superior penetration into complex lumens, multi-channel tubing, and tightly packaged materials, making it suitable for heat- and moisture-sensitive devices that cannot withstand autoclave conditions.

It effectively sterilizes infusion sets, disposable syringes, surgical packs, catheters, urine collection bags, cardiac catheters, vascular stents, intraocular lenses, diagnostic scopes, microsurgical tools, and similar heat-sensitive medical products. It is also used for certain agricultural and food products such as spices and packaged grains.

Two main models are offered: a Semi-Automatic version with analog push-buttons and manual controls, and a Fully Automatic version with PLC and touch-screen HMI for hands-free operation, digital batch tracking, and precise parameter control.

The relevant model (AETOS–2.6) has a working capacity of approximately 2.6 cubic feet (70 liters), chamber size around 12″ (W) × 12″ (H) × 32″ (D), uses a 40-gram sterilant gas cartridge, supports both warm and cold cycles, includes built-in aeration, requires compressed air at 100 psig, and runs on 1 kW power at 220 V single-phase 50 Hz (adjustable to local voltage).

All product-contact components are fabricated from premium AISI 304 / 316 stainless steel for excellent corrosion resistance and easy sanitation. The chamber is typically double-walled with insulation for safety and efficiency.

It features an explosion-proof design, leak detectors, automatic shutoffs, pneumatically actuated ball valves, and compliance with relevant standards such as ATEX and ISO 11135. The inert gas diluent further reduces flammability risks.

The cycle consists of air removal (vacuum), conditioning (humidification and heating), EO exposure (typically 1–2 hours dwell), and aeration/purge with fresh air flushing. An in-built aeration facility is provided to remove EO residues efficiently.

It is used in pharmaceutical, nutraceutical, herbal, Ayurvedic, biotech, cosmetic, and chemical industries, as well as in small-to-medium healthcare facilities needing reliable low-temperature sterilization of sensitive medical devices and supplies.

Countries We Export to

United States | Canada | Mexico | Brazil | Argentina | Chile | Colombia | Peru | Germany | United Kingdom | France | Italy | Spain | Netherlands | Belgium | Switzerland | Sweden | Austria | Denmark | Norway | Poland | Finland | Czech Republic | Hungary | Portugal | Ireland | Greece | Slovakia | Romania | Bulgaria | China | Japan | India | South Korea | Indonesia | Vietnam | Thailand | Malaysia | Philippines | Singapore | Bangladesh | Pakistan | Saudi Arabia | United Arab Emirates | Israel | Turkey | Iran | Qatar | Kuwait | South Africa | Nigeria | Egypt | Algeria | Morocco | Kenya | Ghana | Tunisia | Australia | New Zealand | Russia | Ukraine | Belarus | Kazakhstan | Taiwan | Hong Kong | South Sudan | Uzbekistan | Oman | Jordan | Bahrain | Sri Lanka | Myanmar | Lebanon | Mongolia | Ethiopia | Libya | Angola | Zambia | Zimbabwe | Mozambique | Ivory Coast | Senegal | Uganda | Tanzania | Botswana | Ecuador | Venezuela | Bolivia | Paraguay | Uruguay | Trinidad and Tobago | Panama | Guatemala | Costa Rica | Honduras | El Salvador | Nicaragua | Dominican Republic | Haiti | Cuba

Partner with Industry Experts

Connect with our engineering team to discuss your specific production requirements. We provide customized, cGMP-compliant machinery solutions designed to optimize your manufacturing facility and maximize output.

Countries We Export to

Algeria | Angola | Argentina | Australia | Austria | Bahrain | Bangladesh | Belarus | Belgium | Bolivia | Botswana | Brazil | Bulgaria | Canada | Chile | China | Colombia | Costa Rica | Cuba | Czech Republic | Denmark | Dominican Republic | Ecuador | Egypt | El Salvador | Ethiopia | Finland | France | Germany | Ghana | Greece | Guatemala | Haiti | Honduras | Hong Kong | Hungary | India | Indonesia | Iran | Ireland | Israel | Italy | Ivory Coast | Japan | Jordan | Kazakhstan | Kenya | Kuwait | Lebanon | Libya | Malaysia | Mexico | Mongolia | Morocco | Mozambique | Myanmar | Netherlands | New Zealand | Nicaragua | Nigeria | Norway | Oman | Pakistan | Panama | Paraguay | Peru | Philippines | Poland | Portugal | Qatar | Romania | Russia | Saudi Arabia | Senegal | Slovakia | Singapore | South Africa | South Korea | South Sudan | Spain | Sri Lanka | Sweden | Switzerland | Taiwan | Tanzania | Thailand | Trinidad and Tobago | Tunisia | Turkey | Uganda | Ukraine | United Arab Emirates | United Kingdom | United States | Uruguay | Uzbekistan | Venezuela | Vietnam | Zambia | Zimbabwe

Partner with Industry Experts

Connect with our engineering team to discuss your specific production requirements. We provide customized, cGMP-compliant machinery solutions designed to optimize your manufacturing facility and maximize output.

Adinath International manufactures high-precision vial powder filling machines and complete packaging lines, providing reliable, hygienic, and efficient solutions for global pharmaceutical industries.

Contact Us

©Adinath International | Theme Developed By Pharma Machinery Manufacturer I Website updated on: 25 August 2026